Jingge has passed Chinese, Korean, and England standards, and 95% of its products are exported to Japan, Korea, the Middle East, South America, and parts of Europe. Our quality has earned the trust and recognition of customers worldwide. We will always be your most reliable partner.
The LDG integrated (split-type) electromagnetic flowmeter consists of two main components: a flow sensor and a converter.This upgraded electromagnetic flowmeter series, developed from the LDG model, delivers innovative breakthroughs in design, assembly, and internal architecture. These advancements ensure exceptional precision, stability, and consistency. The product is widely adopted across industries including power generation, metallurgy, chemical processing, petroleum refining, municipal engineering, environmental protection, food processing, and pharmaceutical manufacturing.
The measurement is not affected by changes in fluid density, viscosity, temperature and pressure
The accuracy level is high, up to 0.2
The measurement repeatability is good, and the maximum repeatability can reach 0.03%
The product range covers a wide spectrum, from DN4 to DN2000
Almost no pressure loss, no flow resistance parts
Corrosion resistant, can measure most corrosive conductive liquids
The device provides multiple signal outputs including analog, frequency, and current signals, along with RS485 communication interfaces. It also supports optional wireless communication options such as HART, PROFIBUS, FF, GPRS, NB, and 4G
Basic Specifications of LDG Series Universal Electromagnetic Flowmeters
| Operative norm | JB/T9248-2015 Electromagnetic Flowmeter | ||
| Applicable medium | Conductive liquid,conductivity≥5μS/cm | ||
| Sensor material | Carbon steel,304 stainless steel or 316 stainless steel | ||
| Process connection mode | Threaded connection type | External thread co-nnection | DN15~DN50 |
| Flanged type | Flange joint | DN4~DN2000 | |
| Clamp connection type | Clamp connection | DN15~DN100 | |
| Applicable medium temperature | -20℃to+150℃,see Table 5-1 | ||
| Nominal pressure | PN10 to PN160,Class150 to Class 900,see Table 4-2 for details | ||
| Install ambient temperature | -20℃~+55℃ | ||
| Relative humidity of the installation environment | 5%~95% | ||
| Class of accuracy | 1.0,0.5,0.2 | ||
| Repetitiveness | Greater than one-thid of the absolute value ofthe maximum allowable eror for the accuracy class | ||
| Working power supply | DC24V(9V~36V),AC220V(90V~250V),or 3.6V lithium battery | ||
| Signal output | Flow rate or frequency,4-20mA | ||
| Communication interface | RS485,HART,NB-IoT,or 4G | ||
| Cable inlet | Standard:M20×1.5(6mm~10mm);Explosion-proof:M20×1.5(6mm~10mm) | ||
| Inner lining heat-resistant | PTFE/PFA:-30℃ to+150℃(split type);-30℃to+80℃(integrated type) | ||
| F46:-30℃ to+100℃,split-type;-30℃ to+80℃,integrated-type | |||
| Chloroprene rubber:-15℃~+80℃ | |||
| Polyurethane:-15℃~+60℃ | |||
| Anti-hazard classification | Not explosion-proof or flameproof(ExdibqIIBCT6 Gb) | ||
| Levels of protection | IP65 or IP68 | ||