Protective devices should be installed in environments with rapid pressure changes, vibration, or pulsation.
Do not apply pressure during transportation, installation, or use.
Pressure gauges should be installed horizontally or vertically.
Normal pressure: Generally not exceeding 3/4 of the upper limit of measurement.
Alternating load: Not exceeding 2/3 of the upper limit of measurement.
Various pressure control and alarm systems, hydraulic presses, industrial special oil production lines, etc.
Diameter: 100 mm
Accuracy & Mounting Type
| Item | Classification | Mark |
| Accuracy | 1.5 grade | CL 1.5 CL 1.6 |
Mounting Type | Botom Cannedian, Direc | A-TYPE |
| Botiom Cornecion, Surface | B-TYPE |
Scale Range)/[unit:Mpa]
-0.1~0 -0.1~2 0~100
Material
Case &Cover:STS 304
Bourdon Tub:STS 304,STS 316
Movement :STS 304
Dial :Aluminum (铝)
Connection:STS 316
Rated Voltage and Current of Contact
220V 0.7A/1.0A
Contact From
SPDT*1,SPDT*2
2-contact of High(upper limit), Low(lower limit)
(HighorLow,High &High,High&Low,Low&Low)
![]()